This guide is general information, not legal advice. Requirements differ between England, Wales, Scotland and Northern Ireland and by type of premises. Always confirm intervals with your competent persons, insurers and enforcing authorities.
What counts as statutory maintenance?
Statutory maintenance is the inspection, testing and servicing the law requires to keep people safe. If you are responsible for premises (as an owner, landlord, tenant or employer), some of these duties sit with you even when a contractor does the work.
Across a multi-site estate, the challenge is rarely knowing what the law says. It is proving, site by site and asset by asset, that the work actually happened on time, and that anything found was put right.
The main regimes
| Area | Key legislation and guidance | Typical activities |
|---|---|---|
| Fire safety | Regulatory Reform (Fire Safety) Order 2005 (England and Wales); Fire (Scotland) Act 2005; BS 5839-1; BS 5266-1 | Fire risk assessment; weekly alarm tests and periodic servicing; emergency lighting monthly checks and annual full-duration tests; extinguisher servicing; fire door checks |
| Electrical | Electricity at Work Regulations 1989; BS 7671 | Periodic inspection of the fixed installation (EICR); inspection and testing of portable equipment where risk requires it |
| Gas | Gas Safety (Installation and Use) Regulations 1998 | Servicing and safety checks by Gas Safe registered engineers; annual gas safety records for let accommodation |
| Water hygiene | HSE ACoP L8; HSG274 | Legionella risk assessment; temperature monitoring; flushing little-used outlets; tank and calorifier inspections |
| Asbestos | Control of Asbestos Regulations 2012 | Asbestos register and management plan; periodic re-inspection of known materials; surveys before refurbishment |
| Lifts and lifting equipment | LOLER 1998; PUWER 1998 | Thorough examination, typically every six months for equipment that lifts people and every twelve months otherwise |
| Pressure systems | Pressure Systems Safety Regulations 2000 | Written scheme of examination and periodic examination by a competent person |
How to prove compliance across many sites
Auditors, insurers and clients ask the same questions: what should have happened, did it happen on time, what was found and what was done about it. A system that answers those for every site needs five things.
1. Schedules against the right object
Attach each regime to the site, location, installation or individual asset it covers. A fire alarm servicing schedule belongs to the fire alarm system; emergency lighting tests may belong to each fitting.
2. Automatic release and assignment
Visits that depend on someone remembering to raise a job will eventually be missed. Schedules should release on their own, on your calendar, to the preferred contractor.
3. A clear measure
Measure compliance as planned visits completed within their window, by category. Track compliance after first visit and open remedials alongside it, so a contractor can’t look compliant by attending and leaving the defects.
4. Evidence on the job
Certificates, test results, photos and sign-off should be attached to the job and the asset at the time of the visit, not chased afterwards.
5. Remedials linked back
When an inspection finds a defect, the remedial job should stay linked to the original visit, so you can show the whole story from finding to fix.
Planned maintenance compliance is reported by category with a one-click statutory filter, compliance after first visit, open and awaiting remedials, and an export for audit. See how it works.
Common pitfalls
- Counting jobs, not assets. One “fire servicing” job for a site can hide the fact that half the extinguishers weren’t checked.
- Certificates in inboxes. If evidence lives in email, it isn’t evidence until someone finds it.
- Remedials that drift. A defect noted on an inspection report is a known risk until it’s fixed.
- One calendar for every regime. Different regimes need different periods; some estates (rail, for example) plan in their own periods.